| Key Data Set Information | |||
| Location | ES | ||
| Geographical representativeness description | España | ||
| Reference year | 2024 | ||
| Name |
| ||
| Use advice for data set | Declared modules: A1 Raw materials supply A2 Transport A3 Manufacturing A4 Transport C1 De-construction C2 Transport C3 Waste processing C4 Disposal D Reuse, recovery, recycling potential Reference Lifetime (RSL): Characteristics and properties of the product: Requirements (conditions of use, frequency of maintenance, repair, etc.): | ||
| Technical purpose of product or process | Timber cladding for walls and ceilings; these are panels specifically designed to cover and decorate vertical and horizontal surfaces in interior spaces. These panels are made from different types of wood and its derivatives, offering a wide variety of options in terms of styles and textures. Their main function is to provide an attractive appearance. In addition to their aesthetic value, these kinds of cladding may also have additional properties such as improving the thermal insulation or acoustic or fire performance of a room. They are used in a variety of settings, from residential homes to commercial venues, as a stylish alternative to decorate and personalize different areas. They can be installed in a versatile way, adapting to different methods and systems based on the user’s preferences and the features of the project. This declaration presents the worst case by weight for wall and ceiling cladding products consisting of wood slats or boards fixed to frames or battens of the following three cladding families: • Smooth or molded MDF/Ply cladding: Cladding formed by smooth board of thicknesses varying between 12 mm and 22 mm of different types of wood, fixed to the wall or ceiling by means of pine or spruce battens of the described sections or installed directly on the wall. Finished with natural wood veneer and varnished, HPL veneer or lacquered, with a weight varying from 7.20 to 28.8 kg/m2 between the best and the worst case. Optionally with decorative moldings glued on its surface. • Machined MDF/Ply cladding (acoustic): Cladding formed by smooth board of thicknesses varying between 12mm and 22mm of different types of wood, fixed to the wall or ceiling by means of pine or spruce battens of the described sections and a layer of rock wool or mineral wool of the described thicknesses to provide an acoustic absorption property. Perforated, slotted or micro-perforated machining, removing part of the material to allow its permeability for sound absorption. Finished with natural wood veneer and varnished, HPL veneer or lacquered, with a weight varying from 10.51 to 24.3 kg/m2. • Frame cladding (with fabric) and with slats: Cladding formed by a frame of pine or spruce slats, measuring 20x20, 40x40 and 50x40, fixed to the wall or ceiling by means of pine or spruce battens of the sections described and optionally upholstered in fabric or acoustic fleece. Decorative slats or moldings are fixed on this frame, which can be made of solid hardwood, pine wood or MDF covered with veneer or plywood boards cut into slats with a weight ranging from 10.03 to 31.70 kg/m2. Finished with natural wood veneer and varnished or lacquered. In these kinds of cladding some components are omitted in some cases, either omitting the upholstery or leaving the upholstered frame without slats. Also, the moldings or slats fixed simply on a primary base. | ||
| Classification |
Class name
:
Hierarchy level
| ||
| General comment on data set | Wall and ceiling cladding consisting of wooden slats or boards fixed on frames or battens. | ||
| Copyright | Yes | ||
| Owner of data set | |||
| Quantitative reference | |||
| Reference flow(s) |
| ||
| Biogenic carbon content |
| ||
| Time representativeness | |||
| Data set valid until | 2029 | ||
| Time representativeness description | 2024/12/12 - 2029/12/12 | ||
| Technological representativeness | |||
| Technology description including background system | Product components: It is made up of a 50 x 40 pine wood batten, a 19 mm thick MDF board that will then be transported for machining where it will be grooved, thus losing 1.9% of its mass. The board will also be treated with a water-repellent product and will be equipped with 60 mm thick rock wool for a final finishing with a 1.2 mm thick HPL veneer. The declaration is for the worst case composition of the three families included. <hr>: Base measuring 2362x762 mm; Standard chipboard 30 mm. 1 unit. Longitudinal side panel measuring 2400x781 mm; Standard chipboard 19 mm. 2 units. Transversal side panel measuring 762x781 mm; Standard chipboard 19 mm. 2 units. Roof measuring 2400x800 mm; Chipboard 19 mm. 1 unit. Legs formed by three glued blocks of 30 mm standard chipboard and 19 mm standard chipboard box width slat. Joined using 45x5 mm bichromated screws. | ||
| Type of data set | EPD | ||||
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set |
| ||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
| Commissioner and goal | |
| Commissioner of data set | |
| Data generator | |
| Data set generator / modeller | |
| Data entry by | |
| Time stamp (last saved) | 2026-09-10T21:26:51 |
| Data set format(s) |
|
| Data entry by | |
| Publication and ownership | |
| UUID | b5b57387-4795-412f-b186-117a32fd3508 |
| Date of last revision | 2026-09-10T21:26:51+02:00 |
| Data set version | 00.04.000 |
| Preceding Data set version | |
| Registration authority | |
| Registration number | DAPcons®.NTe.206 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | Your use of this material is subject to the General Terms of Use published on by EPD International AB:s homepage at https://www.environdec.com/contact/General-terms-of-use/. If you have not accepted EPD International AB:s the General Terms of Use, you are not authorized to exploit this work in any manner. |
Indicators of life cycle